  hih-4030/31 series humidity sensors description honeywell has expanded our hih series to include an smd (surface mount device) product line: the new hih 4030/4031. the hih 4030/4031 complements our existing line of non-smd humidity sensors. smd packaging on tape and reel allows for use in high volume, automated pick and place manufacturing, eliminating lead misalignment to printed circuit board through- hole. the hih-4030/4031 series humidity sensors are designed specifically for high volume oem (original equipment manufacturer) users. direct input to a controller or other device is made possible by this sensor?s near linear voltage output. with a typical current draw of only 200 a, the hih-4030/4031 series is often ideally suited for low drain, battery operated systems. tight sensor interchangeability reduces or eliminates oem production calibration costs. individual sensor calibration data is available. the hih-4030/4031 series delivers instrumentation-quality rh (relative humidity) sensing performance in a competitively priced, solderable smd. the hih-4030 is a covered integrated circuit humidity sensor. the hih-4031 is a covered, condensation-resistant, integrated circuit humidity sensor that is factory-fitted with a hydrophobic filter allowing it to be used in condensing environments including industrial, medical and commercial applications. the rh sensor uses a laser trimmed, thermoset polymer capacitive sensing element with on-chip integrated signal conditioning. the sensing element's multilayer construction provides excellent resistance to most application hazards such as condensation, dust, dirt, oils and common environmental chemicals. sample packs are available. see order guide. features ? tape and reel packaging allows for use in high volume pick and place manufacturing (1,000 units per tape and reel) ? molded thermoset plastic housing ? near linear voltage output vs %rh ? laser trimmed interchangeability ? low power design ? enhanced accuracy ? fast response time ? stable, low drift performance ? chemically resistant potential applications ? refrigeration equipment ? hvac (heating, ventilation and air conditioning) equipment ? medical equipment ? drying ? metrology ? battery-powered systems ? oem assemblies
hih-4030/31 series 2 www.honeywell.com/sensing table 1. performance specificat ions (at 5 vdc supply and 25 o c [77 o f] unless otherwise noted.) parameter minimum typical maximum unit specific note interchangeability (first order curve) ? ? ? ? ? 0% rh to 59% rh -5 ? 5 % rh ? 60% rh to 100% rh -8 ? 8 % rh ? accuracy (best fit straight line) -3.5 ? +3.5 % rh 1 hysterisis ? 3 ? % rh ? repeatability ? 0.5 ? % rh ? settling time ? ? 70 ms ? response time (1/e in slow moving air) ? 5 ? s ? stability (at 50% rh in a year) ? 1.2 ? % rh 2 stability (at 50% rh in a year) ? 0.5 ? % rh 3 voltage supply 4 ? 5.8 vdc 4 current supply ? 200 500 a ? voltage output (1 st order curve fit) v out =(v supply )(0.0062(sensor rh) + 0.16), typical at 25 o c temperature compensation true rh = (sensor rh)/(1.0546 ? 0.00216t), t in o c output voltage temp. coefficient at 50% rh, 5 v ? -4 ? mv/o c ? operating temperature -40[ -40] see figure 1. 85[185] o c[ o f] ? operating humidity (hih-4030) 0 see figure 1. 100 % rh 5 operating humidity (hih-4031) 0 see figure 1. 100 % rh ? storage temperature -50[-58] ? 125[257] o c[ o f] ? storage humidity see figure 2. % rh 5 specific notes: 1. can only be achieved with the supplied slope and offset. for hih-4030/31-003 catalog listings only. 2. includes testing outside of recommended operating zone. 3. includes testing for recommended operating zone only. 4. device is calibrated at 5 vdc and 25 o c. 5. non-condensing environment. when liquid water falls on the humidity sensor die, output goes to a low rail condition indicating no humidity. general notes: ? sensor is ratiometric to supply voltage. ? extended exposure to > 90% rh causes a reversible shift of 3% rh. ? sensor is light sensitive. for best performance, shield sensor from bright light. factory calibration data hih-4030/31 sensors may be ordered with a calibration and data printout. see table 2 and the order guide on the back page. table 2. example data printout model HIH-4030-003 channel 92 wafer 030996m mrp 337313 calculated values at 5 v v out at 0% rh v out at 75.3% rh 0.958 v 3.268 v linear output for 3.5% rh accuracy at 25 c zero offset slope sensor rh 0.958 v 30.680 mv/%rh (v out - zero offset)/slope (v out - 0.958)/0.0307 ratiometric response for 0% rh to 100% rh v out v supply (0.1915 to 0.8130)
humidity sensors honeywell sensing and control 3 figure 1. operating environment (non-condensing environment for hih-4030 catalog listings only.) figure 2. storage environment (non-condensing environment for hih-4030 catalog listings only.) 0% 10% 20% 30% 50% 40% 60% 70% 80% 90% 100% -40 20 -20 0 40 60 80 100 120 140 temperature oc recommended storage zone
hih-4030/31 series 4 www.honeywell.com/sensing figure 3. typical output vo ltage vs relative humidity (at 25 oc and 5 v.) 0.5 1 1.5 2 2.5 3 3.5 4 0 20406080100 relative humidity (%rh) output voltage (vdc) sensor response sensor response best linear fit figure 4. typical output voltage (bfsl) vs relative humidity (at 0 oc, 7 0 oc and 5 v.) 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 0 102030405060708090100 relative humidity (%) output voltage (vdc) 0 c 70 c
humidity sensors honeywell sensing and control 5 figure 5. hih-4030 mounting dimensions (for reference only. mm/[in])
hih-4030/31 series 6 www.honeywell.com/sensing figure 6. hih-4031 mounting dimensions (for reference only. mm/[in]) figure 7. hih-4031 pcb landing pattern (for reference only. mm/[in])
humidity sensors honeywell sensing and control 7 figure 8. tape and reel dimensions (for reference only. mm/[in]) 8,00 [0.315] 11,51 [0.453] 2,64 [0.104] 22,25 [0.876] 1,75 [0.069] 24,00 [0.945] 2,64 [0.076] dia. 1,50 [0.059] 2,01 [0.079] 3,99 [0.157] dia. 1,50 [0.059] 3,91 [0.154] 0,343 [0.0135] figure 9. typical application circuit order guide catalog listing description hih-4030-001 covered integrated circuit humidity sensor, smd, 1000 units on tape and reel HIH-4030-003 covered integrated circuit humidity sensor, smd, calibration and data printout, 1000 units on tape and reel hih-4031-001 covered, filtered integrated circuit humidity sensor, smd, 1000 units on tape and reel hih-4031-003 covered, filtered integrated circuit humidity se nsor, smd, calibration and data printout, 1000 units on tape and reel hih-4030-001s sample pack: covered integrated circuit humidity sensor, smd, five units on tape HIH-4030-003s sample pack: covered integrated circuit humidity sensor, smd, calibration and data printout, five units on tape hih-4031-001s sample pack: covered, filtered integrated circuit humidity sensor, smd, sample pack, five units on tape hih-4031-003s sample pack: covered, filtered integrated circui t humidity sensor, smd, calibration and data printout, five units on tape further humidity sensor information see the following associated literature is available on the web : ? product installation instructions ? application sheets: ? humidity sensor performance characteristics ? humidity sensor theory and behavior ? humidity sensor moisture and psychrometrics ? thermoset polymer-based capacitive sensors
sensing and control honeywell 1985 douglas drive north minneapolis, mn 55422 www.honeywe ll.com/sensing 009021-4-en il50 glo printed in usa march 2008 ? 2008 honeywell international inc. all rights reserved. warning misuse of documentation ? the information presented in this product sheet is for reference only. do not use this document as a product installation guide. ? complete installation, operation, and maintenance information is provided in the instructions supplied with each product. failure to comply with these instructions could result in death or serious injury. warranty/remedy honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. honeywell?s standard product warranty applies unless agreed to otherwise by honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. if warranted goods are returned to honeywell during the period of coverage, honeywell will repair or replace, at its option, without charge those items it finds defective. the foregoing is buyer?s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. in no event shall honeywell be liable for consequential, special, or indirect damages. while we provide application assistance personally, through our literature and the honeywell web site, it is up to the customer to determine the suitability of the product in the application. specifications may change without notice. the information we supply is believed to be accurate and reliable as of this printing. however, we assume no responsibility for its use. warning personal injury do not use these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. failure to comply with these instructions could result in death or serious injury. sales and service honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. for application assistance, current specifications, pricing or name of the nearest authorized distributor, contact your local sales office or: e-mail: info.sc@honeywell.com internet: www.honeywell.com/sensing phone and fax: asia pacific +65 6355-2828 +65 6445-3033 fax europe +44 (0) 1698 481481 +44 (0) 1698 481676 fax latin america +1-305-805-8188 +1-305-883-8257 fax usa/canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 fax


▲Up To Search▲   

 